Atrato Downloads:

To download the Atrato Ultrasonic Flowmeter Interface Software, click here (right click and 'Save as')

Atrato Ultrasonic Flowmeters: DATA

This range of ultrasonic flowmeters uses patented technologythat enables our meters to operate over very wide flow rangeswith excellent accuracy over the whole span. The device is atrue inline meter with a direct flow path. The housing is robustand compact with full connectivity with inbuilt terminals anda USB outlet for use with our software package. Our signalprocessing system permits flow measurement over the wholeReynolds number range allowing both viscous and non viscousproducts to metered accurately. The signal discrimination willidentify anomalies in the flow and either ignore them or reportthem depending on the operational requirements.

Atrato Ultrasonic Flowmeters

This flowmeter that is accurate to better than ±1.5% or reading over the whole 250:1 flow range and repeatability is less than ±0.1%. The frequency output and K factor can be scaled to suit the full scale requirements and hence increase meter resolution at the desired flow rate.

Measuring System

The time of flight measuring system measures both the upstream and downstream flight times and half the difference is the velocity of the fluid. Our patented system measures these time differences to an accuracy of better than 200 picoseconds giving our excellent meter performance. As the pipe geometry is known the resulting pulse output is accurate for the volume passed. This performance is further enhanced by our primary signal to noise ratio which is typically 1000:1 and at times as high as 3000:1.

Computer Interface

The USB connection permits the user to directly monitor the rate and total on their laptop as well as altering some of the operating parameters such as the pulse resolution and units. If the rate and total or the analogue boards are used their programming and operation can be accessed directly. At a later date data logging and operation statistics will be possible.

Heritage

The development of the flowmeter began in 2001 with a corporate decision to develop the best noninvasive small bore meter in the world as part of a long term strategic plan. One of the foremost fluid engineering establishments (The Cranfield Institute of Technology) was commissioned to develop the device along with Titan and this joint project has been continuous since that date. Titan have exclusive global rights for the technology which is subject to 2 granted patents and 2 more applications will be made in the near future.

Features

  • Non invasive
  • High reliability
  • Choice of materials
  • ±1.5% of reading
  • No moving parts
  • ±0.1% repeatability
  • 3 Flow ranges
  • Pulse output
  • USB interface
  • 10 Bar rating
  • Viton seals as std.
  • Choice of end fittings
  • 8-24 V dc
  • 70°C Max
  • Flow switch/4-20mA option
  • Rate & total option
  • 250:1 turndown
  • Non metallic options

Standard Materials of construction

Body & tube - PVDF/St St
‘O’ Ring seal - Viton
Output - Pulse
End fittings - 3/8” John Guest



Flows from 2mL to 20 L/Min.

Ideal for:
Drink dispensing
Laboratory tests
Cooling equipment
Active flow alarms
Semiconductor plant
OEM applications